<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>NL 4008 X / 001 &#8211; Jitrasindo</title>
	<atom:link href="http://www.jitrasindo.com/tag/nl-4008-x-001/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.jitrasindo.com</link>
	<description>PT. Jelita Citra Solusindo</description>
	<lastBuildDate>Tue, 27 Aug 2013 06:45:06 +0000</lastBuildDate>
	<language>id</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.5</generator>
	<item>
		<title>NL 4008 X / 001  Half Cell Corrosion Meter</title>
		<link>http://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4008-x-001-half-cell-corrosion-meter/</link>
					<comments>http://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4008-x-001-half-cell-corrosion-meter/#respond</comments>
		
		<dc:creator><![CDATA[jitrasindo]]></dc:creator>
		<pubDate>Tue, 27 Aug 2013 06:45:06 +0000</pubDate>
				<category><![CDATA[Concrete Testing Equipments]]></category>
		<category><![CDATA[HALF CELL CORROSION METER]]></category>
		<category><![CDATA[NL 4008 X / 001]]></category>
		<guid isPermaLink="false">http://www.jitrasindo.com/?p=1812</guid>

					<description><![CDATA[Corrosion of steel is an electrochemical process involving anodic (corroding) and cathodic (passive) areas of the metal. By measuring concrete &#8211; surface electrical potentials relative to a standard reference electrode on a predetermined grid, the presence and location of corrosion and its probable future performance may be assessed. It is possible, by regular measurements, to monitor the behaviour of new&#160;<a href="http://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4008-x-001-half-cell-corrosion-meter/" class="read-more">Continue Reading</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><a href="http://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER.jpg"><img fetchpriority="high" decoding="async" class="alignnone size-medium wp-image-1813" title="NL 4008 X - 001  HALF CELL CORROSION METER" src="http://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER-300x248.jpg" alt="" width="300" height="248" srcset="http://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER-300x248.jpg 300w, http://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER.jpg 327w" sizes="(max-width: 300px) 100vw, 300px" /></a><br />
Corrosion of steel is an electrochemical process involving anodic (corroding) and cathodic (passive) areas of the metal. By measuring concrete &#8211; surface electrical potentials relative to a standard reference electrode on a predetermined grid, the presence and location of corrosion and its probable future performance may be assessed. It is possible, by regular measurements, to monitor the behaviour of new and relatively new structures and thus minimize maintenance costs.<br />
Measurements automatically converted and displayed as copper/copper sulphate equivalent potentials</p>
<p><strong>Technical Specifications :</strong><br />
* Half Cell silver chloride refillable probe (stable &amp; low corrosive)<br />
* Display : 3½ digit plus sign via 12.5 mm LCD<br />
* Range / Resolution : +1999 mV / +1 mV<br />
* Battery operated<br />
* giving typically 1000 hours use with low battery<br />
* indication Automatic : on/off action<br />
* Dimension : 400 x 270 x 130 mm<br />
* Weight : Approx 2 kg</p>