<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HALF CELL CORROSION METER &#8211; Jitrasindo</title>
	<atom:link href="https://www.jitrasindo.com/tag/half-cell-corrosion-meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jitrasindo.com</link>
	<description>PT. Jelita Citra Solusindo</description>
	<lastBuildDate>Tue, 27 Aug 2013 08:07:16 +0000</lastBuildDate>
	<language>id</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.5</generator>
	<item>
		<title>NL 4034 X / 001  Half Cell Corrosion Meter</title>
		<link>https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4034-x-001-half-cell-corrosion-meter/</link>
					<comments>https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4034-x-001-half-cell-corrosion-meter/#respond</comments>
		
		<dc:creator><![CDATA[jitrasindo]]></dc:creator>
		<pubDate>Tue, 27 Aug 2013 08:07:16 +0000</pubDate>
				<category><![CDATA[Concrete Testing Equipments]]></category>
		<category><![CDATA[HALF CELL CORROSION METER]]></category>
		<category><![CDATA[NL 4034 X / 001]]></category>
		<guid isPermaLink="false">http://www.jitrasindo.com/?p=1875</guid>

					<description><![CDATA[Spesifikasi Teknis : This easy to use Half &#8211; Cell gauge measures the condition and potensial corrosion and rebars and steel structures within concrete. When corrosion occurs the ferric oxide protective layer surrounding the concrete breaks down allowing and electrochemical reaction between the steel and the concrete. In the Half Cells test, a reference electrode is passed ofer the surface&#160;<a href="https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4034-x-001-half-cell-corrosion-meter/" class="read-more">Continue Reading</a>]]></description>
										<content:encoded><![CDATA[<p>Spesifikasi Teknis :<br />
This easy to use Half &#8211; Cell gauge measures the condition and potensial corrosion and rebars and  steel structures within concrete.   </p>
<p>When corrosion occurs the ferric oxide protective layer surrounding the concrete breaks down allowing and electrochemical reaction between the steel and the concrete.   </p>
<p>In the Half Cells test, a reference electrode is passed ofer the surface of the concrete and the pottensial voltage  diference is recorded. These potensial voltage reading show where corrosion is likely to be, or is curently present.   </p>
<p>The Half Cells meter is availlable in two models, NL 4034 x /001 and NL 4034 x /002.<br />
▪ NL 4034 X / 001 &#8211;> Model:  Entry  level  gauge without memory  which allows users  to measure<br />
 the Half Cell Potential in conctete  sructures.<br />
▪ NL 4034 X / 002 &#8211;> Model: Supplied with memory and allows  users  to store up to 240,000  readings  in<br />
 either linear or grid batches.<br />
▪ Large, easy to read backlit  display:<br />
    » For easy  viewing  in daR environmeds.<br />
▪ Single handed operalion:<br />
    » Most functions can be accessed &#038; corfirolled  through 4 simple keys.<br />
▪ lntuitive menus  in multiple  languages<br />
    » Allows  use  straight  out of  the box<br />
▪ Rechargeable battery supply:<br />
    » Battery packs  can be charged  inside  or outside  the gauge.<br />
▪ Ergonomically  shaped case:<br />
    » For ease  of use and comforl.  with  a gentle  curve  lo  fit snugly against  the hip.<br />
▪ Powerful CoverMaster@  Software (suplied with the NL 4034  X  / 002 Model):<br />
    » Ullimate data management  tool to store Half-Cell  readings  and produce professional  reports  </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4034-x-001-half-cell-corrosion-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NL 4008 X / 001  Half Cell Corrosion Meter</title>
		<link>https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4008-x-001-half-cell-corrosion-meter/</link>
					<comments>https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4008-x-001-half-cell-corrosion-meter/#respond</comments>
		
		<dc:creator><![CDATA[jitrasindo]]></dc:creator>
		<pubDate>Tue, 27 Aug 2013 06:45:06 +0000</pubDate>
				<category><![CDATA[Concrete Testing Equipments]]></category>
		<category><![CDATA[HALF CELL CORROSION METER]]></category>
		<category><![CDATA[NL 4008 X / 001]]></category>
		<guid isPermaLink="false">http://www.jitrasindo.com/?p=1812</guid>

					<description><![CDATA[Corrosion of steel is an electrochemical process involving anodic (corroding) and cathodic (passive) areas of the metal. By measuring concrete &#8211; surface electrical potentials relative to a standard reference electrode on a predetermined grid, the presence and location of corrosion and its probable future performance may be assessed. It is possible, by regular measurements, to monitor the behaviour of new&#160;<a href="https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4008-x-001-half-cell-corrosion-meter/" class="read-more">Continue Reading</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><a href="http://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER.jpg"><img fetchpriority="high" decoding="async" class="alignnone size-medium wp-image-1813" title="NL 4008 X - 001  HALF CELL CORROSION METER" src="http://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER-300x248.jpg" alt="" width="300" height="248" srcset="https://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER-300x248.jpg 300w, https://www.jitrasindo.com/wp-content/uploads/2013/08/NL-4008-X-001-HALF-CELL-CORROSION-METER.jpg 327w" sizes="(max-width: 300px) 100vw, 300px" /></a><br />
Corrosion of steel is an electrochemical process involving anodic (corroding) and cathodic (passive) areas of the metal. By measuring concrete &#8211; surface electrical potentials relative to a standard reference electrode on a predetermined grid, the presence and location of corrosion and its probable future performance may be assessed. It is possible, by regular measurements, to monitor the behaviour of new and relatively new structures and thus minimize maintenance costs.<br />
Measurements automatically converted and displayed as copper/copper sulphate equivalent potentials</p>
<p><strong>Technical Specifications :</strong><br />
* Half Cell silver chloride refillable probe (stable &amp; low corrosive)<br />
* Display : 3½ digit plus sign via 12.5 mm LCD<br />
* Range / Resolution : +1999 mV / +1 mV<br />
* Battery operated<br />
* giving typically 1000 hours use with low battery<br />
* indication Automatic : on/off action<br />
* Dimension : 400 x 270 x 130 mm<br />
* Weight : Approx 2 kg</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jitrasindo.com/nl-scientific-civil-engineering/concrete-testing-equipments/nl-4008-x-001-half-cell-corrosion-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		